EV Charging Modes |
Mode 3 charging |
|
Rated Voltage |
AC 240V±10%, AC 420V±10% |
|
Rated Current |
Max 16A, Max 32A |
|
Rated Frequency |
50Hz |
|
Over Voltage Category (OVC) |
OVC III |
|
Insulation Resistance |
R > 1 MΩ |
|
AC Withstand Voltage |
1430V |
|
Impulse Dielectric Withstand Voltage (1,2 μs/50 μs)(Uimp) |
4kV |
|
Protection Against Electric Shock |
Class I |
|
Electrical Life(contactcor) |
100,000 |
|
Electrical Life(Interface) |
100,000 |
|
Standby Power Consumption |
<8W |
|
Type of EV Connection |
Case B(Socket version)/Case C(Cable Version) |
|
Universal Interface |
T1:SAE J1772, T2:IEC/EN 62196-2, GB/T:20234.2-2015 |
|
Pollution Degree |
PD 3 |
|
IP Protection Class |
IP54 |
|
Altitude During Operation (m) |
<2000m |
|
Altitude of Test Laboratory |
<50m |
|
Work Humidity |
3%~95% |
|
Operation Temperature |
-25℃- 40℃ |
|
Colling |
Natural Air Cooling |
|
Mounting Method |
Mounted on walls, poles or equivalent positions |
|
Normal Environmental Conditions |
Indoor use; Outdoor use |
|
Product Dimension(mm) |
357*245*123 |
|
Installation Dimension(mm) |
180*280 |
|
The AC charger require external MCB for overload protection and short-circuit protection to be installed in upstream distribution box |
|